Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1463600.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $9,831.00
Current Penalty: $6,882.50
Issuance Date: 04/02/2020
Nr Instances: 1
Nr Exposed: 9
Related Event Code (REC): A;R
Gravity: 5
Report ID: 0523300
Contest Date: 04/27/2020
Final Order: 11/09/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 11/09/2020 | $6,882.50 | Serious | ||
Penalty | C: Contested | 04/27/2020 | $9,831.00 | Serious | ||
Penalty | Z: Issued | 04/02/2020 | $9,831.00 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: On or about February 10, 2020, the Bond Robotics destacker (Asset No. 6307) was not shut down using the lockout/tagout procedure for this machine prior to employees making Syron sensor adjustments.