Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1460987.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,193.00
Current Penalty: $7,000.00
Issuance Date: 03/31/2020
Nr Instances: 2
Nr Exposed: 25
Abatement Date: 04/21/2021
Gravity: 5
Report ID: 0213600
Contest Date:
Final Order: 04/22/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/22/2020 | $7,000.00 | 04/21/2021 | Serious | |
| Penalty | Z: Issued | 03/31/2020 | $8,193.00 | 04/22/2020 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 02/05/2020; where the employer did not develop and document specific energy control procedures for machines and equipment such as, but not limited to: the Vacuum Heat Treat Furnace (asset #108645) electrical, mechanical and pneumatic energy. b) On or about 02/13/2020; where energy control procedures were not utilized for set up operations such as, but not limited to: plant 17 - pump and motor test bays. Employees set up test apparatus without securing energy isolating devices by locking them in the "off" position. ABATEMENT CERTIFICATION REQUIRED