Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1460930.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,675.00
Current Penalty: $6,506.00
Issuance Date: 04/08/2020
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 05/30/2020
Gravity: 5
Report ID: 0524700
Contest Date:
Final Order: 05/04/2020
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/04/2020 | $6,506.00 | 05/30/2020 | Serious | |
| Penalty | Z: Issued | 04/08/2020 | $8,675.00 | 05/01/2020 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6) a) On or about November 26, 2019, the employer did not ensure that energy control application steps to control the electrical energy source were implemented prior to maintenance and servicing tasks being performed on the 6540 slitting head. Employees were exposed to crushing hazards between the slitter rollers when wrapping carpet around the slitter head to cover the knives while eneregized.