Violation Detail
Standard Cited: 19261052 C01 I Stairways.
Inspection Nr: 1453605.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,241.00
Current Penalty: $4,241.00
Issuance Date: 06/18/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 5
Report ID: 0214500
Contest Date:
Final Order: 07/17/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 06/18/2020 | $4,241.00 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) Front Interior Stairway to 1st Floor - Employees were exposed to fall hazards of approximately 9 feet while accessing the 1st floor framing deck utilizing a steel/concrete stairway without any handrail, on or about 1/7/20.
Translate