Violation Detail
Standard Cited: 19100178 G02 Powered industrial trucks.
Inspection Nr: 1418894.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $7,577.00
Current Penalty: $5,304.00
Issuance Date: 12/12/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 5
Report ID: 0213400
Contest Date:
Final Order: 01/03/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/03/2020 | $5,304.00 | Serious | ||
| Penalty | Z: Issued | 12/12/2019 | $7,577.00 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.178(g)(2): Facilities shall be provided for protecting charging apparatus from damage by trucks. A) 1240-1242 Cranbury South River Rd Cranbury, NJ 08512 The battery charging apparatus were located at ground level and unprotected from damage by power industrial trucks. Condition noted on or about 7/29/2019