Violation Detail
Standard Cited: 19100333 C03 Selection and use of work practices
Inspection Nr: 1390866.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,842.00
Current Penalty: $1,100.00
Issuance Date: 09/04/2019
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 09/19/2019
Gravity: 5
Report ID: 0625500
Contest Date:
Final Order: 09/26/2019
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/26/2019 | $1,100.00 | 09/19/2019 | Serious | |
| Penalty | Z: Issued | 09/04/2019 | $2,842.00 | 09/19/2019 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.333(c)(3): If work is to be performed near overhead lines, the lines were not deenergized and grounded, or other protective measures provided before work is started. If the lines are to be deenergized, arrangements were not made with the person or organization that operates or controls the electric circuits involved to deenergize and ground them. If protective measures, such as guarding, isolating, or insulating, were provided, these precautions did not prevent employees from contacting such lines directly with any part of their body or indirectly through conductive materials, tools, or equipment. On or about April 1, 2019, employees were exposed to an electrical hazard while trimming branches from a Bil-Jack Aerial Lift Model XLB 3830 DC and using extendable tools near unguarded overhead energized electrical power lines.