Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1378859.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,525.00
Current Penalty: $8,525.00
Issuance Date: 04/24/2019
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 05/07/2019
Gravity: 5
Report ID: 0524700
Contest Date:
Final Order: 05/16/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/16/2019 | $8,525.00 | 05/07/2019 | Serious | |
| Penalty | Z: Issued | 04/24/2019 | $8,525.00 | 05/07/2019 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: a. On or February 14, 2019, the employer did not ensure that employees who setup the TD-95 router were trained in the skills required for the safe application, usage, and removal of energy controls. Employees that setup the machine's stop-blocks and changed cutting bits were not trained to isolate and/or render energy sources safe.
Translate