Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1347220.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,536.00
Current Penalty: $4,000.00
Issuance Date: 10/18/2018
Nr Instances: 3
Nr Exposed: 2
Abatement Date: 11/14/2018
Gravity: 5
Report ID: 0522000
Contest Date:
Final Order: 10/31/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/31/2018 | $4,000.00 | 11/14/2018 | Serious | |
Penalty | Z: Issued | 10/18/2018 | $8,536.00 | 11/14/2018 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires. a) A shaft on Filler Line 'A' at the operators station was not guarded or covered exposing employees to rotating parts. b) A shaft on the Filler Line 'A' at the start of the line near the kettles was not guarded or covered exposing employees to rotating parts. c) A shaft attached to the kettle pump was not guarded or covered exposing employee to rotating parts.