Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1331781.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,467.00
Current Penalty: $3,166.00
Issuance Date: 09/26/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 11/09/2018
Gravity: 5
Report ID: 0213600
Contest Date: 10/18/2018
Final Order: 12/26/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | J: ALJ Decision | 12/26/2018 | $3,166.00 | 11/09/2018 | Serious | |
| Penalty | C: Contested | 10/19/2018 | $6,467.00 | 11/09/2018 | Serious | |
| Penalty | Z: Issued | 09/26/2018 | $6,467.00 | 11/09/2018 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 07/20/2018, Throughout the facility, employer did not conduct periodic inspections of the Lockout/Tagout procedures for machines such as, but not limited to table saw( SCMI model SI 16 W). ABATEMENT CERTIFICATION REQUIRED