Violation Detail
Standard Cited: 19260600 A06 I Equipment.
Inspection Nr: 1315546.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 11/21/2018 7
Initial Penalty: $3,880.00
Current Penalty: $3,880.00
Issuance Date: 11/05/2018
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 10
Report ID: 0419400
Contest Date:
Final Order: 01/25/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 11/05/2018 | $3,880.00 | 11/21/2018 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1926.600(a)(6)(i): For lines rated 50 kV or below, minimum clearance between the lines and any part of the crane or load shall be 10 feet; (a) On the jobsite - On or about May 10, 2018 the Volvo dump truck made contact with a primary electrical transmission line when it was raised from its resting position. A ten (10) foot clearance was not maintained between the truck and the energized power lines.