Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1304288.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Not Completed - Worksite Changed
Initial Penalty: $3,880.00
Current Penalty: $3,880.00
Issuance Date: 07/11/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 07/19/2018
Gravity: 10
Report ID: 1032500
Contest Date:
Final Order: 08/13/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 07/11/2018 | $3,880.00 | 07/19/2018 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder a) Residential construction site, 1349 Cimmaron Court, Middleton, ID 83644: On or about March 23, 2018 and at times prior thereto; employees accessed a 4:12, 20 foot roof using a portable ladder that was not extended at least three feet above the second level roof, and it was placed on an unstable roof surface which was wet from frost; exposing employees to slip/fall hazards onto concrete ground if the ladder were to deflect or slip off its support. Note* Abatement certification AND documentation are required for this item.