Violation Detail
Standard Cited: 19260451 C01 General requirements.
Inspection Nr: 1247161.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Not Completed - Worksite Changed
Initial Penalty: $4,268.00
Current Penalty: $2,774.20
Issuance Date: 01/09/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 01/22/2018
Gravity: 10
Report ID: 0317000
Contest Date:
Final Order: 05/24/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/24/2018 | $2,774.20 | 01/22/2018 | Serious | |
Penalty | Z: Issued | 01/09/2018 | $4,268.00 | 01/22/2018 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows: a) Jobsite: Employees were working from and around a tubular welded frame scaffold, approximately 5 feet wide 32 feet in height and 8 feet in length, without the use of guys, ties or braces; thus exposing employees to scaffold collapse hazards. Condition was noted on or about 12 JUL 2017.