Violation Detail
Standard Cited: 19260502 B04 Fall protection systems criteria and practices.
Inspection Nr: 1246060.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $6,972.00
Current Penalty: $4,688.00
Issuance Date: 09/22/2017
Nr Instances: 1
Nr Exposed: 10
Abatement Date:
Gravity: 5
Report ID: 0215800
Contest Date:
Final Order: 10/24/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/24/2017 | $4,688.00 | Serious | ||
| Penalty | Z: Issued | 09/22/2017 | $6,972.00 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1926.502(b)(4): When the 200 pound (890 N) test load specified in paragraph (b)(3) of this section was applied in a downward direction, the top edge of the guardrail deflected to a height less than 39 inches (1.0 m) above the walking/working level: a) On or about 7/11/2017, Nicholas Ferrante Building, OCC Drive: Employees performing roofing work on the lower roof were utilizing a guardrail system which had a top rail that deflected to 26 inches above the walking/ working level. Employees exposed to falls of 29 feet.