Violation Detail
Standard Cited: 19100134 H02 I Respiratory Protection.
Inspection Nr: 1245161.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,704.00
Current Penalty: $5,000.00
Issuance Date: 12/22/2017
Nr Instances: 2
Nr Exposed: 15
Abatement Date: 09/12/2019
Gravity: 5
Report ID: 0524200
Contest Date: 01/18/2018
Final Order: 08/12/2019
Related Event Code (REC): C
Emphasis:
Substance: 1591
Substance: C141
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 08/12/2019 | $5,000.00 | 09/12/2019 | Serious | |
Penalty | C: Contested | 02/06/2018 | $5,704.00 | 01/05/2018 | Serious | |
Penalty | Z: Issued | 12/22/2017 | $5,704.00 | 01/05/2018 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
NOTE: Construction Reference: 1926.103. The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.134 of this chapter. 29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: a) On July 6, 2017, the employer did not ensure that employee(s) wearing respiratory protection, stored their respirators in a manner that protected them from contamination and dust. (1) Two Clemco Apollo 600 Series Supplied Air Respirators (SARs), issued for common use during lead removal activities were stored on top of Axxiom Manufacturing Inc. abrasive blasting pots outside a lead containment located on the 2nd floor. Wipe samples confirmed lead and cadmium contamination on the inside visor of the two SARs. (2) A visibly contaminated North 7700 Series Silicone Half Mask Respirator was stored inside the clean change area on the 3rd floor (located between the lunchroom and the shower area) in proximity to clean clothes of employees. Wipe samples of the inside of the respirator confirmed lead and cadmium contamination (Pb and Cd).