Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1224761.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 05/08/2017 2
Initial Penalty: $12,675.00
Current Penalty: $7,605.00
Issuance Date: 04/18/2017
Nr Instances: 1
Nr Exposed: 10
Related Event Code (REC):
Gravity: 10
Report ID: 0625400
Contest Date:
Final Order: 05/04/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/04/2017 | $7,605.00 | 05/08/2017 | Serious | |
Penalty | Z: Issued | 04/18/2017 | $12,675.00 | 05/08/2017 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about April 12, 2017, in the feather building, Employer had no detailed energy control procedures developed for multi energy source equipment, such as the feather hydrolyzer and the feather preheater. The equipment can operate as a system and therefore all energy sources need to be controlled. Energy sources of steam, heat, mechanical and electrical exposed employees to the hazards of being caught in rotating parts, struck by materials, and burned from heat.