Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1207592.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 05/05/2017 2
Initial Penalty: $9,959.00
Current Penalty: $9,959.00
Issuance Date: 04/27/2017
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0418600
Contest Date:
Final Order: 05/17/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/17/2017 | $9,959.00 | 05/05/2017 | Serious | |
Penalty | Z: Issued | 04/27/2017 | $9,959.00 | 05/05/2017 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a) Repelletizer #1 (Old); On or about January 26, 2017 and at times prior thereto the employer exposed employees to potential hazardous energies in that employees were required to work on the Repelletizer to replace blades on the cutter without shutting it down and locking it out in accordance with the company's Lockout program established procedures.