Violation Detail
Standard Cited: 19100147 C04 II A The control of hazardous energy (lockout/tagout).
Inspection Nr: 1204354.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 06/30/2017 2
Initial Penalty: $6,972.00
Current Penalty: $4,000.00
Issuance Date: 04/06/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0524500
Contest Date:
Final Order: 05/01/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/01/2017 | $4,000.00 | 06/30/2017 | Serious | |
Penalty | Z: Issued | 04/06/2017 | $6,972.00 | 04/17/2017 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(4)(ii)(A): The energy control procedures did not contain a specific statement on the intended use of the procedure. On or about January 20, 2017, Polyconversions, Inc. had an employee perform maintenance and servicing operations on equipment within the facility, and the employer did not develop, document, and utilize energy control procedures with a specific statement of the intended use of the procedure.