Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1190726.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,873.00
Current Penalty: $4,436.50
Issuance Date: 01/25/2017
Nr Instances: 5
Nr Exposed: 2
Abatement Date: 02/09/2017
Gravity: 10
Report ID: 0625700
Contest Date:
Final Order: 02/17/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/17/2017 | $4,436.50 | 02/09/2017 | Serious | |
Penalty | Z: Issued | 01/25/2017 | $8,873.00 | 02/09/2017 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): On or about November 9, 2016, at Ludwig Buildings Enterprises, LLC the employer failed to ensure that the Lockout/Tag out program included specific procedural steps for shutting down equipment. Maintenance employees conduct Lockout/ Tag out procedures in order to work on equipment.