Violation Detail
Standard Cited: 19100134 F01 Respiratory Protection.
Inspection Nr: 1185452.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 04/10/2017 2
Initial Penalty: $5,070.00
Current Penalty: $0.00
Issuance Date: 03/03/2017
Nr Instances: 1
Nr Exposed: 13
Related Event Code (REC): C
Gravity: 10
Report ID: 0636900
Contest Date: 04/07/2017
Final Order: 09/07/2018
Emphasis:
Substance: 0685
Substance: 0689
Substance: 1520
Substance: 1620
Substance: 1840
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | R: Review Commission | 09/07/2018 | $0.00 | 04/10/2017 | Serious | |
Penalty | C: Contested | 04/14/2017 | $5,070.00 | 04/10/2017 | Serious | |
Penalty | Z: Issued | 03/03/2017 | $5,070.00 | 04/10/2017 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): On or about October 17, 2016 and at times prior to, employee(s) were not fit tested prior to wearing full face Allegro supplied air respirators and exposed to metal fumes, such as but not limited to hexavalent chromium while spray welding Alcro wire.