Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1181334.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 04/19/2017 2
Initial Penalty: $6,971.00
Current Penalty: $4,531.15
Issuance Date: 03/24/2017
Nr Instances: 2
Nr Exposed: 4
Related Event Code (REC):
Gravity: 5
Report ID: 0523400
Contest Date:
Final Order: 04/18/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/18/2017 | $4,531.15 | 04/19/2017 | Serious | |
Penalty | Z: Issued | 03/24/2017 | $6,971.00 | 04/19/2017 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(4)(ii): 29 CFR 1910.147(c)(4)(ii): The procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A-D): (a) The energy control procedure number "LOTO-RB26", which the employer had developed for Converting Machines RB126, RB426, and RB536, was deficient in that it did not address techniques to be utilized for control of pneumatic energy. (b) The energy control procedure number "LOTO-RB26B", which the employer had developed for Converting Machines RB226 and RB326, was deficient in that it did not address techniques to be utilized for control of pneumatic energy.