Violation Detail
Standard Cited: 19260451 E04 VIII General requirements.
Inspection Nr: 1160826.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $8,017.00
Current Penalty: $8,017.00
Issuance Date: 01/05/2017
Nr Instances: 1
Nr Exposed: 18
Abatement Date:
Gravity: 5
Report ID: 0420600
Contest Date:
Final Order: 01/24/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/24/2017 | $8,017.00 | Serious | ||
Penalty | Z: Issued | 01/05/2017 | $8,017.00 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1926.451(e)(4)(viii): Stairtowers (scaffold stairway/towers) were not provided with a landing platform at least 18 inches (45.7 cm) wide by at least 18 inches (45.7 cm) long at each level: a. At the west side of the south building, employees were exposed to a 27 foot fall hazard while using a stairtower erected to provide access to the scaffold frames without being provided with landing platforms at each level, on or about 07/07/2016.