Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1157543.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 11/30/2016 2
Initial Penalty: $6,236.00
Current Penalty: $4,000.00
Issuance Date: 10/07/2016
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0524500
Contest Date:
Final Order: 11/01/2016
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/01/2016 | $4,000.00 | 11/30/2016 | Serious | |
Penalty | Z: Issued | 10/07/2016 | $6,236.00 | 11/08/2016 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On or about June 22, 2016, E.R.H. Enterprises, Inc. had employees exposed to amputation hazards from an unguarded pulley associated with the belt and pulley power transmission of a water pump, which was connected to Poly 1 and 2 Tanks at the water treatment plant in Danville, Illinois.