Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1154956.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,000.00
Current Penalty: $3,350.00
Issuance Date: 07/21/2016
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 08/02/2016
Gravity: 5
Report ID: 0317500
Contest Date:
Final Order: 08/10/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/10/2016 | $3,350.00 | 08/02/2016 | Serious | |
Penalty | Z: Issued | 07/21/2016 | $5,000.00 | 08/02/2016 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): Instances including, but not limited to, the following: a) Job site, 140 Commerce Drive, Freedom, PA: On or about June 14, 2016, the employer did not ensure that all energy isolating devices were located and physically operated in such a manner so as to disconnect power to the machine in that during die changing activities on the Landis pipe thread machine, company identification number 003509, the electrical power was left connected, with power on to the machine during the work.