Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1046746.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $2,800.00
Current Penalty: $1,400.00
Issuance Date: 07/15/2015
Nr Instances: 1
Nr Exposed: 4
Abatement Date:
Gravity: 5
Report ID: 0213600
Contest Date:
Final Order: 08/05/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/05/2015 | $1,400.00 | Serious | ||
Penalty | Z: Issued | 07/15/2015 | $2,800.00 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) Plant - M&R Sprint 200 dryer - On or about 3/16/15, two pulleys, located about 64 inches high from the floor, were not guarded. b) Plant - M&R Sprint 200 dryer - On or about 3/1615, a pulley, located about 10 inches from the floor, was not guarded. NO ABATEMENT CERTIFICATION REQUIRED