Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 1044804.015
Citation: 01002A
Citation Type: Serious
Abatement Status:
Initial Penalty: $4,400.00
Current Penalty: $0.00
Issuance Date: 08/19/2015
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 09/15/2015
Gravity: 5
Report ID: 0418100
Contest Date:
Final Order: 09/03/2015
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/03/2015 | $0.00 | 09/15/2015 | Serious | |
Penalty | Z: Issued | 08/19/2015 | $4,400.00 | 09/15/2015 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On or about March 5, 2014, employees were exposed to hazards of in-running nip points and/or injury resulting from belt breakage on line #3. a. Drive belt accessible from end and bottom of guard on line #3. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).