Violation Detail
Standard Cited: 19260451 C01 General requirements.
Inspection Nr: 1003442.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $6,300.00
Current Penalty: $6,300.00
Issuance Date: 04/14/2015
Nr Instances: 1
Nr Exposed: 17
Abatement Date:
Gravity: 10
Report ID: 0936300
Contest Date:
Final Order: 05/07/2015
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/07/2015 | $6,300.00 | Serious | ||
| Penalty | Z: Issued | 04/14/2015 | $6,300.00 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows: Dusit Thani Hotel Jobsite, Sixth Floor, Banquet Room 1 and 2: Pacific Rim Land Development permitted the use of a four tier fabricated frame orange mobile scaffold that had a height to base ratio greater than 4 to 1. The mobile scaffold was measured to be 16 feet, 7.5 inches tall and 4 feet wide and it was not restrained from tipping. On October 18, 2014, the mobile scaffold toppled over fatally injuring a plumber.
Translate