Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1003085.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 05/06/2015 2
Initial Penalty: $7,000.00
Current Penalty: $4,200.00
Issuance Date: 04/17/2015
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 10
Report ID: 0627500
Contest Date: 05/04/2015
Final Order: 11/27/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 11/27/2015 | $4,200.00 | 05/06/2015 | Serious | |
Penalty | C: Contested | 05/13/2015 | $7,000.00 | 05/06/2015 | Serious | |
Penalty | Z: Issued | 04/17/2015 | $7,000.00 | 05/06/2015 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Pump Room 2: On or about October 22, 2014 the employer did not develop, document and utilize procedures for the control of potentially hazardous energy. Employees were exposed to safety and health hazards while replacing piping without informing the onsite employer of their lockout tagout procedures.