Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 997533.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,850.00
Current Penalty: $2,310.00
Issuance Date: 01/16/2015
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 02/11/2015
Gravity: 5
Report ID: 0524700
Contest Date:
Final Order: 02/11/2015
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/11/2015 | $2,310.00 | 02/11/2015 | Serious | |
Penalty | Z: Issued | 01/16/2015 | $3,850.00 | 02/11/2015 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: P&W Painting Contractors, Inc. - Toledo, Ohio: On or about September 24, 2014, the employer did not ensure that employees who maintained the Pangborn shot blast machine were trained in the skill required for the safe application, usage, and removal of energy controls. Employees were not trained to follow energy isolating steps when entering the machine to retrieve parts.