Violation Detail
Standard Cited: 19100147 C05 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 995311.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $7,000.00
Issuance Date: 03/04/2015
Nr Instances: 2
Nr Exposed: 24
Abatement Date: 07/19/2015
Gravity: 10
Report ID: 0729300
Contest Date: 03/24/2015
Final Order: 08/26/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 08/26/2015 | $7,000.00 | 07/19/2015 | Serious | |
Penalty | C: Contested | 03/25/2015 | $0.00 | 03/25/2015 | Serious | |
Penalty | Z: Issued | 03/04/2015 | $0.00 | 03/25/2015 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices were not singularly identified: a. There were no blocking devices specifically identified for the purpose of isolation of gravity, such as for the scrap tables at cells 5, 8, 9, 13. b. There were no lockout devices specifically identified for the purpose of isolation of pneumatic energy, such as for covering air hose ends, removed from quick disconnects. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).