Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 978559.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $7,000.00
Issuance Date: 10/29/2014
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 12/03/2014
Gravity: 10
Report ID: 0524200
Contest Date:
Final Order: 11/06/2014
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/06/2014 | $7,000.00 | 12/03/2014 | Serious | |
| Penalty | Z: Issued | 10/29/2014 | $7,000.00 | 12/03/2014 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a) Bun Production - On or about May 27, 2014, the Bakery Equipment/Winkler (BEW) Loader was not turned off or shut down during servicing and maintenance activity.
Translate