Violation Detail
Standard Cited: 19260300 A General requirements.
Inspection Nr: 976981.015
Citation: 01002
Citation Type: Serious
Abatement Status: Not Completed - Worksite Changed
Initial Penalty: $2,000.00
Current Penalty: $2,000.00
Issuance Date: 11/07/2014
Nr Instances: 1
Nr Exposed: 9
Abatement Date: 11/14/2014
Gravity: 5
Report ID: 0317000
Contest Date:
Final Order: 02/02/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 11/07/2014 | $2,000.00 | 11/14/2014 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.300(a): Hand tool(s), power tool(s) or similar equipment were not maintained in a safe condition. a) Jobsite: Ground level - On or about 5/1/14, the Sawzall reciprocating saw was not maintained in safe condition as the energized conductors were unprotected thus exposing employees to potential shock hazards.