Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 952731.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,825.00
Current Penalty: $1,530.00
Issuance Date: 04/18/2014
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 08/25/2014
Gravity: 5
Report ID: 0729300
Contest Date: 05/02/2014
Final Order: 10/31/2014
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 10/31/2014 | $1,530.00 | 08/25/2014 | Serious | |
| Penalty | C: Contested | 05/15/2014 | $3,825.00 | 05/07/2014 | Serious | |
| Penalty | Z: Issued | 04/18/2014 | $3,825.00 | 05/07/2014 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: Hydraulics Section: Required machine-specific energy control procedures were not developed and instituted for machines such as, but not limited to, CNC Machine T-28 and Bridgeport mill.
Translate