Violation Detail
Standard Cited: 19100094 A03 I Ventilation.
Inspection Nr: 946449.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,000.00
Current Penalty: $2,000.00
Issuance Date: 01/03/2014
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 02/07/2014
Gravity: 5
Report ID: 0112600
Contest Date:
Final Order: 02/10/2014
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/10/2014 | $2,000.00 | 02/07/2014 | Serious | |
| Penalty | Z: Issued | 01/03/2014 | $4,000.00 | 02/07/2014 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.94(a)(3)(i): Blast-cleaning enclosures were not exhaust ventilated in such a way that a continuous inward flow of air was maintained at all openings in the enclosure during the blasting operation. (a) Cleaning and repair department: On or about 11/5/13, the bead blaster was not exhaust ventilated in such a way that a continuous inward flow of air was maintained at all openings in the enclosure during the blasting operation, in accordance with this subpart, and was leaking dust out to the surrounding area.