Violation Detail
Standard Cited: 19100146 C05 II C Permit-required confined spaces
Inspection Nr: 928383.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,300.00
Current Penalty: $6,300.00
Issuance Date: 02/03/2014
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 03/19/2014
Gravity: 10
Report ID: 0420600
Contest Date:
Final Order: 02/27/2014
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 02/03/2014 | $6,300.00 | 03/19/2014 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.146(c)(5)(ii)(C): Employees entered into permit spaces that met the conditions set forth in 29 CFR 1910.146(c)(5)(i) but before an employee entered the space, the internal atmosphere was not tested with a calibrated direct-reading instrument: a) Brownwood Development Manhole Intersection of Buena Vista Blvd. and 44A - The confined space was entered without testing the internal atmosphere.