Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 914601.015
Citation: 01002
Citation Type: Serious
Abatement Status:
Initial Penalty: $7,000.00
Current Penalty: $0.00
Issuance Date: 08/22/2013
Nr Instances: 1
Nr Exposed: 45
Abatement Date: 09/26/2013
Gravity: 10
Report ID: 0418100
Contest Date:
Final Order: 09/12/2013
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/12/2013 | $0.00 | 09/26/2013 | Serious | |
| Penalty | Z: Issued | 08/22/2013 | $7,000.00 | 09/26/2013 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: On or about 06/26/2013 at 6400 Cantrell Road Flowery Branch, GA; employees performing tool and die changes and cleaning operations of machines including but not limited to the number 1 wire draw line did not apply locks to the lines and depended solely on the interlock system exposing them to caught-in and struck-by hazards.