Violation Detail
Standard Cited: 19260651 C02 Specific Excavation Requirements.
Inspection Nr: 902723.015
Citation: 01002
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $2,800.00
Current Penalty: $1,680.00
Issuance Date: 07/10/2013
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0418200
Contest Date:
Final Order: 08/06/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/06/2013 | $1,680.00 | Serious | ||
Penalty | Z: Issued | 07/10/2013 | $2,800.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: (a) Trench, new storm management facility located between Lots #5 & #6 on South Sherwood Road, Smyrna, GA 30082: Employees installing new concrete sewer lines in a trench which measured approximately 5-feet, 10-inches wide by 6-feet deep by 40-feet long were not provided with a safe means of egress, i.e. ladder and or ramp.