Violation Detail
Standard Cited: 19100179 B05 Overhead and gantry cranes.
This violation item has been deleted.
Inspection Nr: 893847.015
Citation: 01002
Citation Type: Serious
Abatement Status:
Initial Penalty: $4,675.00
Current Penalty: $0.00
Issuance Date: 07/12/2013
Nr Instances: 1
Nr Exposed: 100
Abatement Date: 07/24/2013
Gravity: 5
Report ID: 0522500
Contest Date: 08/02/2013
Final Order: 09/02/2014
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/02/2014 | $0.00 | 07/24/2013 | Serious | |
Penalty | C: Contested | 08/08/2013 | $4,675.00 | 07/24/2013 | Serious | |
Penalty | Z: Issued | 07/12/2013 | $4,675.00 | 07/24/2013 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.179(b)(5): Crane(s) with more than one hoisting unit did not have the rated load marked on each hoisting unit or load block: a. In building number 2, the employer did not ensure the magnet used on crane 3 to lift materials had the load rating marked on it.