Violation Detail
Standard Cited: 19100146 K03 II Permit-required confined spaces
This violation item has been deleted.
Inspection Nr: 427231.015
Citation: 01002
Citation Type: Serious
Abatement Date: 11/26/2012
Initial Penalty: $7,000.00
Current Penalty: $0.00
Issuance Date: 11/01/2012
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0336000
Contest Date: 11/16/2012
Final Order: 12/18/2012
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 01/08/2013 | $7,000.00 | 11/26/2012 | Serious | |
Penalty | F: Formal Settlement | 12/18/2012 | $0.00 | 11/26/2012 | Serious | |
Penalty | Z: Issued | 11/01/2012 | $7,000.00 | 11/26/2012 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.146(k)(3)(ii): An authorized entrant entered a permit space and did not have the other end of the retrieval line attached to a mechanical device or fixed point outside the permit space in such a manner that rescue could begin as soon as possible. A): Rescar Companies - On or about 5/11/12, an employee had entered a rail tank car (#GATX31606) to perform work. The employee was wearing a harness but the lifeline was not attached to a fixed point outside of the confined space.