Violation Detail
Standard Cited: 19100253 B04 III Oxygen-fuel gas welding and cutting.
Inspection Nr: 426233.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,600.00
Current Penalty: $2,520.00
Issuance Date: 05/23/2012
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 06/22/2012
Gravity: 5
Report ID: 0316300
Contest Date:
Final Order: 06/11/2012
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/11/2012 | $2,520.00 | 06/22/2012 | Serious | |
| Penalty | Z: Issued | 05/23/2012 | $3,600.00 | 06/22/2012 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least a.) Walashek Industrial and Marine, Shop Area: On or about 05/10/12, the employer had oxygen cylinders and acetylene cylinders in storage that were not separated by 20 feet, or by a barrier at least 5 1/2 feet high with a fire rating of at least 1/2 hour.