Violation Detail
Standard Cited: 19100119 D02 ID Process safety management of highly hazardous chemicals.
This violation item has been deleted.
Inspection Nr: 313028805
Citation: 01002
Citation Type: Serious
Abatement Status:
Initial Penalty: $4,500.00
Current Penalty: $0.00
Issuance Date: 07/08/2010
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 07/27/2010
Gravity: 10
Report ID: 0625700
Contest Date: 07/30/2010
Final Order:
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/01/2010 | $0.00 | 07/27/2010 | Serious | |
| Penalty | Z: Issued | 07/08/2010 | $4,500.00 | 07/27/2010 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard: REFINERY
29 CFR 1910.119(d)(2)(i)(D): Process safety information pertaining to the techno logy of the process did not include the safe upper and lower limits for such ite ms as temperatures, pressures, flows or compositions: This violation was observe d on or about 01/19/2010, where the employer did not maintain a listing of the safe upper and lower limits for the following safety d evice: a)Pressure safety valves (PSV's), Pressure Sensor High & Low (PSH & PSL) b)Flow safety valves (FSV's) c)Temperature Sensor High & Low (TSH & TSL) d)Level Sensor High & Low (LSH & LSL) These safety devices are located on, but are not limited to, the High & Low pressure Separators (MBD-0500 & -0600), Oil Heater/Tr eaters (NBK-0100 & -0200), Line Heater (BAP-0050), Vent Scrubber (MBF-0100) and Water Skimmer (MBM-0100). By not developing, obtaining, documenting the above in formation, the employees were exposed to fire, explosion and chemical exposure. Pursuant to 29 CFR 1903.19(d), within 10 calendar days of the date of the citati on, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps it is taking to ensure that the Hi gh and Low limits are documented on the Safety Analysis Function Evaluation (SAFE) chart, PSV Inspecti on reports, and other process documentation.
Translate