Standard Cited: 5A0001 OSH Act General Duty Paragraph

Inspection Nr: 312367576

Citation: 01002

Citation Type: Serious

Abatement Status: X

Initial Penalty: $5,000.00

Current Penalty: $3,500.00

Issuance Date: 07/14/2009

Nr Instances: 10

Nr Exposed: 12

Abatement Date: 12/31/2009

Gravity: 10

Report ID: 0215800

Contest Date: 07/27/2009

Final Order: 11/20/2009

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty J: ALJ Decision 11/20/2009 $3,500.00 12/31/2009 Serious  
Penalty Z: Issued 07/14/2009 $5,000.00 08/17/2009 Serious  

Text For Citation: 01 Item/Group: 002 Hazard: CRUSHING

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a fire hazard: The following natural gas heaters and their supply lines were not maintained and operated in a safe manner: a)Rod and Bar, Near Furnace Pulpit, on or about 1/20/09: Natural gas supply lines and regulators for heaters were exposed to damage while in walkways. b)Crane Repair, on or about 2/3/09: Natural gas supply lines and regulators for heaters were exposed to damage while in walkways. c)Bar Anneal #2, on or about 2/3/09: A natural gas valve was not provided with a handle. The supply line for a natural gas torch was crimped. d)Bar Finish, Bulldozer 126 area, on or about 2/6/09: The supply line for a natural gas heater was exposed to damage while in a walkway. e)Press, Outside of Millwrights Crib, on or about 2/17/09: The supply line for a natural gas heater was exposed to damage, was crimped and crushed. aaa)Bar Finish, Bldg. 70, Sonic Inspection, north wall, on or about 2/5/09: The supply line for a natural gas heater was exposed to damage while in the walkway. bbb)CPM Bldg., behind the old lunch room, on or about 2/13/09: The supply line for a natural gas heater was exposed to damage while in the walkway. Among other methods, feasible and acceptable abatement methods to correct these hazards are to: 1.Ensure that natural gas supply lines and regulators are protected from physical damage. 2.Install and maintain the natural gas fired heaters, and their delivery system in accordance with NFPA 54, National Fuel Gas Code, sections 5.8.4, 5.12, 5.6.5, 9.6.4, 7.2.1, 9.6.1. Abatement documentation must be submitted for these items.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close