Powered by GoogleTranslate

Violation Detail

Standard Cited: 5A0001 OSH Act General Duty Paragraph

Inspection Nr: 308477660

Citation: 01002

Citation Type: Serious

Abatement Status: X

Initial Penalty: $1,600.00

Current Penalty: $1,040.00

Issuance Date: 08/24/2006

Nr Instances: 2

Nr Exposed: 2

Abatement Date: 08/27/2007

Gravity: 02

Report ID: 0316700

Contest Date:

Final Order:

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 09/14/2006 $1,040.00 08/27/2007 Serious  
Penalty Z: Issued 08/24/2006 $1,600.00 08/27/2007 Serious  

Text For Citation: 01 Item/Group: 002 Hazard: DUST&FUMES

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to hazards of potential fire and explosion because of the lack of bonding and grounding of pneumatic piping, lack of detectors to sense hot materials or sparks in the pneumatic system and the lack of blower motors not fitted with overload trips may produce ignition, leading to dust explosion inside the pneumatic conveying system or overload electric motors: (a)Flour Room - The pneumatic system used to convey the flour dust had some sections that were plastic pipe and not grounded and bonded. The pneumatic system was not equipped with detectors to sense hot materials or sparks which could potential lead to a dust explosion inside system. The blowers and motors for the pneumatic conveying system were not fitted with overload trips and could lead to ignition of airborne flour combustible dust, on or about May 4, 2006. VERIFICATION REQUIRED ABATEMENT NOTE: AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THESE HAZARDS IS TO COMPLY WITH NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 61 "STANDARD FOR THE PREVENTION OF FIRE AND DUST EXPLOSIONS IN AGRICULTURAL AND FOOD PROCESSING FACILITIES" AND FOLLOWING THE RECOMMENDATIONS FROM THE BOOK "DUST EXPLOSION, PREVENTION AND PROTECTION". THIS INCLUDES THE FOLLOWING: (a)ENSURE THAT ALL PIPING FOR THE PNEUMATIC CONVEYING SYSTEM IS GROUNDED AND BONDED PER SECTION 11.1 OF NFPA 61. (b)ENSURE THAT THE PNEUMATIC SYSTEM IS EQUIPPED WITH DETECTORS TO SENSE HOT MATERIAL OR SPARKS PER SECTION 3.4.2 OF "DUST EXPLOSION PREVENTION AND PROTECTION". (c)ENSURE THAT THE BLOWERS AND MOTORS OF THE PNEUMATIC CONVEYING SYSTEM ARE EQUIPPED WITH OVERLOAD TRIPS PER SECTION 3.4.2 OF "DUST EXPLOSION PREVENTION AND PROTECTION". PROGRESS REPORT DUE EVERY 90 DAYS. FIRST REPORT IS DUE NOVEMBER 25, 2006.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.