Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 280226.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $4,900.00
Issuance Date: 07/11/2012
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 07/18/2012
Gravity: 10
Report ID: 0213100
Contest Date:
Final Order: 08/01/2012
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/01/2012 | $4,900.00 | 07/18/2012 | Serious | |
Penalty | Z: Issued | 07/11/2012 | $7,000.00 | 07/18/2012 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples: of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc. a) Thermoforming area- On and before 5/24/12- Irwin #2 and Irwin #5 Rennco autopackers point of operation and rotating parts were not equipped with machine guarding.