Violation Detail
Standard Cited: 19260651 J02 Specific Excavation Requirements.
This violation item has been deleted.
Inspection Nr: 1877875.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $2,270.00
Current Penalty: $0.00
Issuance Date: 04/24/2026
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 5
Report ID: 0215800
Contest Date:
Final Order: 05/12/2026
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/12/2026 | $0.00 | Serious | ||
| Penalty | Z: Issued | 04/24/2026 | $2,270.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. a) On or about February 27, 2026, at the worksite, 215 College Avenue, Ithaca, NY 14850: The employer failed to ensure employees working in an excavation were protected from materials at the edge of the excavation falling into the excavation.