Violation Detail
Standard Cited: 19261053 B05 I Ladders.
Inspection Nr: 1867454.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $9,268.00
Current Penalty: $9,268.00
Issuance Date: 02/13/2026
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 10
Report ID: 0420600
Contest Date:
Final Order: 03/13/2026
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 02/13/2026 | $9,268.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.1053(b)(5)(i):Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support): a) For the residential construction site at 22705 Nebula Way, Land O Lakes, FL 34637, on or about 01/08/2026, the employer exposed employees to fall hazards, in that, employees were using a metal extension ladder to access/egress a 9 ft. high roof, and the ladder was at a supported angle such that the horizontal distance from the top support to the foot of the ladder was only approximately one-half of the working length of the ladder as it was used.
Translate