Violation Detail
Standard Cited: 19260651 C02 Specific Excavation Requirements.
Inspection Nr: 1830070.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $6,621.00
Current Penalty: $3,972.60
Issuance Date: 12/05/2025
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 5
Report ID: 0317900
Contest Date:
Final Order: 12/22/2025
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/22/2025 | $3,972.60 | Serious | ||
| Penalty | Z: Issued | 12/05/2025 | $6,621.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.651(c)(2):A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) 1090 Swedesford Rd. Ambler, PA 19002- On or about June 9, 2025, employees accessed a 7 foot deep excavation without a safe means of egress. An A-frame ladder in the excavation that employees utilized for egress did not extend 3 feet above the height of the ground.