Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1799110.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $12,768.00
Current Penalty: $7,660.80
Issuance Date: 04/21/2025
Nr Instances: 1
Nr Exposed: 6
Abatement Date:
Gravity: 5
Report ID: 0420600
Contest Date:
Final Order: 05/06/2025
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/06/2025 | $7,660.80 | Serious | ||
| Penalty | Z: Issued | 04/21/2025 | $12,768.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. a.) At the worksite, located at 6245 Frandor Pl Apollo Beach, FL 33572; On or about 1/22/25, the employer exposed employees to fall hazards of approximately 9 ft & 14 ft, in that, an extension ladder did not extend 3 ft past the landing surface for employees conducting roofing operations on a single family residential home.