Violation Detail
Standard Cited: 19100253 B02 II Oxygen-fuel gas welding and cutting.
Inspection Nr: 1798371.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,965.00
Current Penalty: $2,000.00
Issuance Date: 04/07/2025
Nr Instances: 2
Nr Exposed: 5
Abatement Date:
Gravity: 1
Report ID: 0317500
Contest Date:
Final Order: 04/30/2025
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/30/2025 | $2,000.00 | Serious | ||
| Penalty | Z: Issued | 04/07/2025 | $4,965.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders were not secured or located where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: a) In the Spectro Lab, on or about January 16, 2025 - A compressed gas cylinder of argon was not secured so that they could not be knocked over by passing employees. b) Small Furnace Area, on or about January 16, 2025 - Compressed gas cylinders including oxygen, argon, carbon dioxide and acetylene were not secured so that they could not be knocked over by passing employees and/or vehicular traffic including fork trucks.
Translate