Violation Detail
Standard Cited: 19100217 C01 I Mechanical power presses.
Inspection Nr: 1789984.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,550.00
Current Penalty: $16,000.00
Issuance Date: 03/19/2025
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 03/21/2025
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 04/22/2025
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/22/2025 | $16,000.00 | 03/21/2025 | Serious | |
Penalty | Z: Issued | 03/19/2025 | $16,550.00 | 03/21/2025 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.217(c)(1)(i):The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press. a) Airstream, Inc. on or about November 25, 2024 at the location of 1001 West Pike Street Jackson Center, Ohio 45334: The employer did not ensure existing guards were effectively adjusted to protect employees from the point of operation. Due to this condition, employees tasked with operating the Minister Punch Press (TS030) were not adequately protected from the point of operation, exposing them to pinch point hazards.