Violation Detail
Standard Cited: 19100147 F03 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1789309.015
Citation: 01002
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $13,005.00
Current Penalty: $5,000.00
Issuance Date: 03/13/2025
Nr Instances: 1
Nr Exposed: 26
Abatement Date:
Gravity: 5
Report ID: 0522000
Contest Date:
Final Order: 03/31/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/31/2025 | $5,000.00 | Other | ||
Penalty | Z: Issued | 03/13/2025 | $13,005.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(f)(3)(ii)(D): Group lockout or tagout devices shall be used in accordance with the procedures required by paragraph (c)(4) of this section including, but not necessarily limited to, the following specific requirements: Each authorized employee shall affix a personal lockout or tagout device to the group lockout device, group lockbox, or comparable mechanism when he or she begins work, and shall remove those devices when he or she stops working on the machine or equipment being serviced or maintained. a) On or about January 16, 2025, the employer did not ensure that each authorized employee affixed a personal lockout or tagout device to the group lockbox when performing preventive maintenance on equipment, including but not limited to the Horkos Machining Center on the Subaru Line 3 OP-10 #1. Employees were exposed to pneumatic, pressurized water/coolant and electrical energy.